Reference Standards GB/T 12706.3-2020 “Extruded Insulation Power Cables and Accessories with Rated Voltages from 1kV (Uₘ=1.2kV) to 35kV (Uₘ=40.5kV) – Part 3: Cables with Rated Voltage 26/35kV (Uₘ=40.5kV)”; GB/T 15065-2019 “General Rules for Flame-retardant Control Cables or Cables or Optical Cables”.
Reference Standards 《GB/T 12706.2-2020》Extruded Insulation Power Cables and Accessories with Rated Voltages from 1kV (Uₘ=1.2kV) to 35kV (Uₘ=40.5kV) – Part 2: Cables with Rated Voltages from 6kV (Uₘ=7.2kV) to 30kV (Uₘ=36kV); 《GB/T 15065-2019》General Rules for Flame-Retardant Control Cables, Cables or Optical Cables.
Reference Standards GB/T 12706.1-2020 “Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1 kV (Um=1.2 kV) to 35 kV (Um=40.5 kV) – Part 1: Cables for Rated Voltages of 1 kV (Um=1.2 kV) and 3 kV (Um=3.6 kV)”; GB/T 19666-2019 “General Rules for Flame-retardant and Fire-resistant Wires, Cables or Optical Cables”; IEC 60502-1 “Power Cables with Extruded Insulation for Rated Voltages from 1 kV (Um=1.2 kV) to 30 kV (Um=40.5 kV) – Part 1: Cables for Rated Voltages of 1 kV (Um=1.2 kV) and 3 kV (Um=3.6 kV)”;
• Conductor: Stranded pure nickel wire • Rated voltage: 300/500V • Insulation: Glass fiber rope braiding + fluorinated gold mica tape + glass fiber braiding • Operating temperature: -60~+500℃ • Colors: White, yellow, red, black, green
• Conductor: Stranded nickel-plated copper wire • Rated voltage: 300/500V • Insulation: Glass fiber rope braiding + fluorophlogopite tape + glass fiber braiding • Operating temperature: -60~+400℃ • Colors: White, red, blue, black, green, yellow-green
• Conductor: Stranded bare copper wire • Colors: White, red, green, black, yellow, yellow-green • Insulation: Glass fiber rope braiding + fluorophlogopite tape + glass fiber braiding • Operating temperature: -60~+350℃ • Rated voltage: 300/500V
• Conductor: Silver-plated or nickel-plated copper wire • Insulation: PFA Teflon (Soluble Polytetrafluoroethylene) • Temperature Range: -65℃~+250℃ • Rated Voltage: 600V • Colors: White, Blue, Red, Black, Brown, Yellow, Green, Transparent, Yellow-Green • Outer Diameter Tolerance: ±0.1mm
• Conductor: Tinned copper, silver-plated wire or nickel-plated copper wire • Insulation: Silicone rubber • Temperature range: -60℃ ~ +200℃ • Colors: White-Red-Black-Green-Brown-Yellow-Transparent-Yellow-Green • Outer diameter tolerance: ±0.1mm • Rated voltage: 300V/500V
Reference Standard: 《CQC 1146-2020》Technical Specification for Certification of Waterproof Rubber-sheathed Flexible Wires with Rated Voltage 450/750V.
Reference Standard: 《GB/T 5013-2008》(IEC 60245:1994) Rubber Insulated Cables with Rated Voltage up to 450/750V Part 6: Welding Machine Cables
Reference Standard:(GB/T 5013-2008) Rubber-insulated cables with rated voltage up to 450/750V