Generally used for indoor, tunnel, cable trench and underground direct burial laying. The cable can withstand a certain degree of laying traction.
《GB/T 12706.2-2020》Extruded Insulation Power Cables and Accessories with Rated Voltages from 1kV (Uₘ=1.2kV) to 35kV (Uₘ=40.5kV) - Part 2: Cables with Rated Voltages from 6kV (Uₘ=7.2kV) to 30kV (Uₘ=36kV); 《GB/T 15065-2019》General Rules for Flame-Retardant Control Cables, Cables or Optical Cables.
Applicable to extruded insulation power cables with rated voltages of 6kV and 30kV for fixed installation in distribution networks or industrial installations.
| Model | Name | Category | Voltage Rating | Operating Temperature | Laying Temperature | Characteristic Description | Number of Cores
(Production Standard) |
Conductor Nominal Cross-section (mm²) |
| YJV | Copper core cross-linked polyethylene insulated polyvinyl chloride sheathed power cable | ZR ZA ZB ZC |
6/6KV 6/10KV 8.7/10KV 8.7/15KV 12/20KV 18/20KV 18/30KV |
≤90°C | ≥0°C | Easy to use, chemical corrosion resistance, and not limited by laying difference | 1 core 3 cores |
25~630 |
| YJLV | Aluminum core cross-linked polyethylene insulated polyvinyl chloride sheathed power cable | ZR ZA ZB ZC |
6/6KV 6/10KV 8.7/10KV 8.7/15KV 12/20KV 18/20KV 18/30KV |
≤90°C | ≥0°C | Easy to use, chemical corrosion resistance, and not limited by laying difference | 1 core 3 cores |
25~630 |
| YJV22 | Copper core cross-linked polyethylene steel tape armored polyvinyl chloride sheathed power cable | ZR ZA ZB ZC |
6/6KV 6/10KV 8.7/10KV 8.7/15KV 12/20KV 18/20KV 18/30KV |
≤90°C | ≥0°C | Easy to use, chemical corrosion resistance, and not limited by laying difference | 1 core 3 cores |
25~630 |
| YJLV22 | Aluminum core cross-linked polyethylene steel tape armored polyvinyl chloride sheathed power cable | ZR ZA ZB ZC |
6/6KV 6/10KV 8.7/10KV 8.7/15KV 12/20KV 18/20KV 18/30KV |
≤90°C | ≥0°C | Easy to use, chemical corrosion resistance, and not limited by laying difference | 1 core 3 cores |
25~630 |
| YJV32 | Copper core cross-linked polyethylene fine steel wire armored polyvinyl chloride sheathed power cable | ZR ZA ZB ZC |
6/6KV 6/10KV 8.7/10KV 8.7/15KV 12/20KV 18/20KV 18/30KV |
≤90°C | ≥0°C | Easy to use, chemical corrosion resistance, and not limited by laying difference | 1 core 3 cores |
25~630 |
| YJLV32 | Aluminum core cross-linked polyethylene fine steel wire armored polyvinyl chloride sheathed power cable | ZR ZA ZB ZC |
6/6KV 6/10KV 8.7/10KV 8.7/15KV 12/20KV 18/20KV 18/30KV |
≤90°C | ≥0°C | Easy to use, chemical corrosion resistance, and not limited by laying difference | 1 core 3 cores |